ANEL-Elektronik AG - Comparison of the devices |
||||||||||||||
| NET-PwrCtrl - | I Generation | II Generation | ||||||||||||
| HOME | PRO | POWER | POWER 19" | IO - PRO | IO - POWER | IO - 19" | ADV - PRO | ADV- POWER | ADV - 19" | HUT2 - HV | HUT2 - HV-S | HUT2 - LV | HUT2 - LV-S | |
|
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
| Sockets / relays (controllable) | 4 (3) | 8 (8) | 8 (8) | 8 (8) | 8 (8) | 8 (8) | 8 (8) | 8 (8) | 8 (8) | 8 (8) | 8 relay |
8 relay |
8 relay |
8 relay potential free |
| Input / Output - I / O (Bit) | - | - | - | - | 8 | 8 | 8 | - | - | - | 8 | 8 | 8 | 8 |
| Supply voltage (V) | 230VAC | 100-240VAC | 100-240VAC | 100-240VAC | 100-240VAC | 100-240VAC | 100-240VAC | 100-240VAC | 100-240VAC | 100-240VAC | 100-240VAC 50-60Hz |
100-240VAC 50-60Hz |
8-30VAC 10-40VDC |
8-30VAC 10-40VDC |
| Power consumption | 1,9 W | 3,6 W | 3,6 W | 3,6 W | 3,6 W | 3,6 W | 3,6 W | 3,6 W | 3,6 W | 3,6 W | 3,0 W | 3,0 W | 1,6 W | 1,6 W |
| Max. Load each outlet | 2300 VA |
2300 VA |
2300 VA |
2300 VA |
2300 VA |
2300 VA |
2300 VA |
2300 VA |
2300 VA |
2300 VA |
max. 16 A | max. 16 A | max. 16 A | max. 16 A |
Max. Load of all outlets |
2300 VA |
2300 VA |
4600 VA |
4600 VA |
2300 VA |
4600 VA |
4600 VA |
2300 VA |
4600 VA |
4600 VA |
||||
| Mains terminals (10A): | 1 x | 1 x | 2 x | 2 x | 1 x | 2 x | 2 x | 1 x | 2 x | 2 x | via panel |
via panel 8 x 16A |
via panel 8 x 16A |
via panel 8 x 16A |
| Sensor port (RJ45) | ||||||||||||||
| HTML - Changeable | - | - | - | - | ||||||||||
| Wake on LAN (WOL) | - | - | - | - | ||||||||||
| I/O input -> switch socket (relay) with edge control and toggle | - | - | - | - |
|
- | - | - | ||||||
| IP assignment: DHCP, Manual | all |
|||||||||||||
| User - System | all |
|||||||||||||
| Automatic time adjustment | all |
|||||||||||||
| Sun timer - according to the calculations sunrises and sunsets | - | - | - | - | ||||||||||
| Free choice of the HTTP port (0-65535) | all |
|||||||||||||
| E-mail at the event. | all |
|||||||||||||
| UDP, Ajax interface for own control | all |
|||||||||||||
| Keepalive Function | all |
|||||||||||||
| Timers per socket | 5 | 5 | 5 | 5 | 5 | 5 | 5 | 5 | 5 | 6 | 5 | 5 | 5 | 5 |
| Automatic and time-delayed (0-18,2h) switch on the sockets after the start (power failure). | - | - | - | - | ||||||||||
| Pulse switching: To control external devices, only one pulse with adjustable length can be generated when switching. | - | - | - | - | ||||||||||
| Switching distance of the relays with simultaneous switching can be determined in the range 0-255 milliseconds. | - | - | - | - | ||||||||||
| Automatic switching on of the sockets after the start (power failure). | - | - | - | - | - | - | - | - | - | - | ||||
| Logbook of the last 40 events. | - | - | - | - | - | - | - | - | - | - | ||||
| Logbook of the last 128 events. Power failures are registered. (Logbook is kept without power). | - | - | - | - | ||||||||||
| Save configuration | all |
|||||||||||||
| Firmware upgrade via Ethernet | all |
|||||||||||||
| Sturdy aluminum housing, child safety in the sockets | - | - | - | - | ||||||||||
| Online-Shop | HOME | PRO | POWER | POWER 19" | IO - PRO | IO - POWER | IO - 19" | ADV - PRO | ADV- POWER | ADV - 19" | HUT2 - HV | HUT2 - HV-S | HUT2 - LV | HUT2 - LV-S |
© 2019 ANEL-Elektronik AG - Comparison of the devices |
||||||||||||||